Solis inverter troubleshooting

Common Solis inverter issues for installer partners, covering battery communication failures and KF1 connectivity problems with causes and resolution steps

Skrivet av Mats Wallén
Uppdaterad idag

Solis inverter troubleshooting

This article covers common issues encountered during and after Solis inverter installations. Each issue includes likely causes and resolution steps. Problems are often inter-related — work through each cause systematically before escalating.

Battery communication failure (batt_comm_fail)

What it means: The Solis inverter cannot communicate with the battery over the CAN bus. This error appears in the Solis Cloud app as batt_comm_fail.

Likely causes and resolution steps:

  • Incorrect battery model set in the inverter

  • Incorrect inverter model set in the HV box

  • Battery error

  • Faulty CAN cable between HV box and inverter

No communication between KF1 and Solis inverter

What it means: The KF1 controller cannot communicate with the Solis inverter. This prevents remote control and monitoring of the inverter from the KanEL system.

Likely causes and resolution steps:

  • Old inverter firmware

  • Faulty or incorrectly specified cable between KF1 and inverter

Inverter range

Installation guide

Solis 5–10K

support.kanel.se/kf1-solis-installation

Solis 12–20K

support.kanel.se/kanel-kf1-to-solis-12-20k-installation

Solis 30–50K

support.kanel.se/kanel-kf1-to-solis-30-50k-installation

- Replace the cable if it does not meet the specified requirements or shows signs of damage